banner

Products

Hospital Laboratory Blood Collection Tube

Hospital Laboratory Blood Collection Tube

Blood Collection Tube Specification:Size: 1.8ml, 2.7ml, 3ml, 5ml, 7ml(other size available by OEM)For venous blood colle
SHARE

Description

Basic Info.
Model NO. CY-NY001
Usage Clinical Haematology, Cross Matching, Blood Group
Validity 3 Years
Cap Color Red/Yelleo/Green/Blue/Black/Grey
OEM Yes
Transport Package as Customer′s Requirements
Specification 13*75mm 13*100mm 16*100mm 12*75mm 12*100mm
Trademark Junnuo
Origin Shandong
HS Code 9018019000
Production Capacity 1000000PCS/Day
Product Description

Hospital Laboratory Blood Collection Tube--Plastic Tube---Medical Consumables Shandong Chengwu

Hospital Laboratory Blood Collection Tube--Plastic Tube---Medical Consumables Shandong Chengwu

Hospital Laboratory Blood Collection Tube--Plastic Tube---Medical Consumables Shandong Chengwu


Blood Collection Tube Specification:Size: 1.8ml, 2.7ml, 3ml, 5ml, 7ml(other size available by OEM)For venous blood collectionNon toxic, non pyrogenicUsed with multi sample needleQuality: ISO13485: 2007Material: PET, GlassSterilization: Gamma RadiationShelf life: 18-24 monthsPacking: 100PCS per box or as customer's requirements
Vol.:1-5ML,5-7ML,7-10ML.
Additive Type available:Blood Collection Tube + No additiveBlood Collection Tube + EDTA k2Blood Collection Tube + EDTA k3Blood Collection Tube + Heparin sodiumBlood Collection Tube + Heparin lithiumBlood Collection Tube + Sodium citrate1: 9Blood Collection Tube + Sodium citrate1: 4Blood Collection Tube + Seprate Gel+Clot activatorBlood Collection Tube + Fluoride/oxalateBlood Collection Tube + Clot activator

Hospital Laboratory Blood Collection Tube--Plastic Tube---Medical Consumables Shandong Chengwu

1. Gel & Clot Activator Tube
Category: Serum blood collection tube
Additive: Gel and Clot Activator vacuum blood Tube
Material: PET(plastic) or Glass
Tube size: 13*75mm, 13*100mm, 16*100mm
Volume: 1ml-8.5ml
Packing: 100pcs/rack*12rack/carton
Cap stopper: Yellow cap, plastic safety stopper or rubber stopper
Gel & Clot Activator vacuum blood collection Tube aims to obtain high quality serum specimen for biochemistry, immunology and serology tests in clinical inspection. Inside the tube there is some gel present at the bottom, which is a pure substance and is very stable in physico-chemistry properties. Otherwise, the gel can avoid high-temperature decomposition and small molecules precipitation, hence it greatly reduces the risk of testing equipment clogging.
Gel can thoroughly separate blood cell and serum, specially keep serum nonpolluted from exchanging blood component.
Gongdong medical is a professional manufacturer vacuum blood collection tube.
GD Vacuum Blood Collection System include:
1. Vacuum blood collection tube:
A. Serum blood collection tube (Red Plain Tube, Red Pro-coagulation Tube, Yellow Gel & Clot Activator Tube)
B. Plasma blood collection tube (Blue PT tube, Double wall PT tube, Green Heparin Tube, Green Gel & Heparin Tube, Grey Glucose tube, Lavender Gel & EDTA Tube)
C. Whole blood collection tube(Lavender EDTA Tube, Black ESR Tube, 120*8mm ESR tube and ESR rack)
2. Micro Blood collection tube, Capillary blood collection tube, Non-vacuum blood collection tube
3. Multi sample needle, Butterfly needle
4. Normal tube holder, Tube holder with safety cover
5. Sharp container, Transfer-store box for vacuum blood collection tube.
Gel and clot activator tube is used for blood serum biochemistry, immunology and drug testing, etc. There uniformly sprays the coagulant on the surface inside the tube, which will greatly shorten the clotting time.
As the imported separation gel from Japan is pure substance, very stable in physicochemical property, it can well stand high-temperature so that the gel will maintain a stable status during the storage and transportation process.
The gel will get solidified after centrifugation and completely separate serum from fibrin cells just like a barrier, which effectively prevents the substance exchange between blood serum and cells. Serum collection efficiency is improved and high-quality serum will be obtained, thus it comes to more authentic testing result.
Keep the serum stable for more than 48 hours, no obvious change will happen on its biochemical features and chemical compositions, then the tube could be directly used in sampling analyzers.
- Time for complete clot retraction: 20-25min
- Centrifugation speed: 3500-4000r/m
- Centrifugation time: 5min
- Recommended storage temperature: 4-25ºC
2.Clot Activator Tube
Clot activator tube is used in the blood collection for biochemistry and immunology in medical inspection. It is suitable for wide range of operating temperature. With special treatment, the tube inner surface is very smooth where high-quality coagulant sprays uniformly. The blood sample will completely contact with coagulant and clot within 5-8min. High-quality serum thus is obtained by later centrifugation, free from the cracking of blood corpuscle, hemolysis, separation of fibrin protein, etc.
Hence the serum can meet the requirements of fast clinic and emergency serum test.
- Time for complete clot retraction: 20-25min
- Centrifugation speed: 3500-4000r/m
- Centrifugation time: 5min
- Recommended storage temperature: 4-25ºC

Specification:
Cap colorClinical applicationVolumeSpecimenAdditive
RedSerum biochemistry2/3/4/5ml SerumNone (A silicone coating on the interior walls reduces adherence of the red cells to tube walls)
YellowQuick serum biochemistry test2/3/4/5mlSerumSeparation Gel and Clot Activator (A silicone coating on the interior walls reduces adherence of the red cells to tube walls)
OrangeQuick serum biochemistry test2/3/4/5mlSerumClot Activator : fibrin ferment (A silicone coating on the interior walls reduces adherence of the red cells to tube walls)
BlueBlood coagulation test2/3/4/5mlPlasmaAnticoagulant : Blood should be 9 times than sodium citrate
GreyBlood glucose test2/3/4/5mlPlasmaAnticoagulant : EDTA, Sodium Fluoride
GreenBlood rheologytest2/3/4/5mlPlasmaAnticoagulant : Lithium heparin or Sodium heparin
AquaQuick plasma biochemistry test2/3/4/5mlPlasmaSeparation gel, Lithium heparin
WhiteNucleic acid detection test2/3/4/5mlPlasmaSeparation gel, EDTA
PurpleWhole blood test1.8/2.7/3.6mlWhole BloodAnticoagulant : EDTA-2K or EDTA-3K
BlackESR2/3/4/5ml Whole BloodAnticoagulant : Blood should be 4 times than sodium citrate

Hospital Laboratory Blood Collection Tube--Plastic Tube---Medical Consumables Shandong Chengwu




Our Contact